Heating and cooling
Staff who are too hot or too cold tire faster, and heat stresses them too. Heating and cooling keep your facility in the range where they are comfortable, from 18 to 24 C, shown in your temperature unit. The facility has one indoor temperature. It drifts toward the outdoor temperature, and your heating and cooling pull it back.
There are two tiers. Single units are placed one at a time. The central system is an HVAC Central Unit, Air Ducts and Vents working together. All of them are in the climate group on the Utilities tab.
Comfort and staff
Outside the comfort band your staff pay for it in fatigue, and heat costs them stress as well.
- Above 24 C, staff on duty gain fatigue and stress. The further past 24 C, the faster it builds.
- Below 18 C, staff on duty gain fatigue. Cold does not add stress.
- A heat wave adds fatigue for everyone on duty, even with cooling. It is lighter while the indoor temperature stays at 25 C or below.
- Staff within 3 tiles of a running Window AC Unit take half the heat fatigue. Staff within 3 tiles of a Box Fan take 35 percent of it. The two do not stack. The stronger one counts.
- Staff within 3 tiles of a running Space Heater take half the cold fatigue.
- The Window AC Unit is noisy. Staff within 2 tiles of one gain stress while it runs, so keep it a little away from where people stand to work.
Coverage
How hard heating and cooling pull depends on coverage: the floor tiles your units serve, divided by the floor tiles in the facility. A bigger facility needs more units to pull just as hard. Coverage stops counting at 150 percent, so units past that do not make the pull any stronger.
Power matters too. A unit on a circuit in a brownout counts at 40 percent. A unit on a tripped circuit counts for nothing.
Window AC Units cool only while the indoor temperature is above 24 C. Space Heaters heat only while it is below 18 C. Inside the band they leave the temperature alone. The HVAC Central Unit works to its own thermostat. See HVAC Central Unit. Both tiers can run in the same facility.
Single units
Prices below are in the default currency, US dollars. They render in the currency you picked.
| Unit | Cost | Power | Serves | Placement |
|---|---|---|---|---|
![]() | $250.00 | 12 kW while cooling | 15 floor tiles | In an outside wall or window, facing in |
![]() | $120.00 | 15 kW while heating | 12 floor tiles | On a floor tile |
![]() | $80.00 | 3 kW at all times | Staff within 3 tiles, against heat only | On a floor tile |
A Window AC Unit only fits in a wall or window on the outer edge of the building, with indoor floor on one side and open air on the other. Interior walls refuse it with "Window AC Unit goes in an outside wall or window, facing in." The unit sits on the indoor tile against that wall and faces into the room.
Removing that wall or window puts the unit back in storage. A wall turned into a window, or a window back into a wall, keeps it.
A Window AC Unit draws its 12 kW on the circuit while the outdoor or indoor temperature is above 24 C. A Space Heater draws its 15 kW while the outdoor or indoor temperature is below 18 C. A Box Fan always draws 3 kW.
Central system
The HVAC Central Unit, Air Ducts and Vents work together. The unit makes the air, ducts carry it, and vents let it into rooms.
| Part | Cost | Power | Notes |
|---|---|---|---|
| HVAC Central Unit | $2,400.00 | 40 kW while running, 2 kW idle | 2x2, outdoors, touching an outside wall. Feeds up to 8 Vents. |
| Air Duct | $20.00 per tile | None | One size. Carries air 40 tiles along the duct from a working unit. |
| Vent | $90.00 | None | Ceiling mount. Serves up to 20 floor tiles of its room. |
HVAC Central Unit

The unit sits outside, against the building. Every tile of the 2x2 unit has to be outdoors, with no roof over it, and one side has to touch a wall or window whose other side is indoor floor. A unit under a roof is refused with "HVAC Central Unit stands outdoors, beside an outside wall." A unit that touches no outside wall is refused with "HVAC Central Unit must touch an outside wall of the building."
The unit both heats and cools. Its tooltip reads "Heats below 19.5 C, cools above 22.5 C, stops at 21 C." Once it starts, it keeps going until the indoor temperature reaches 21 C, then idles. It never pushes past 21 C. Running, it draws 40 kW on its circuit. Idle, it draws 2 kW. All central units share one thermostat. It runs only while live Vents serve some floor.
The unit needs power from a fusebox circuit. In a brownout it still runs, at 40 percent. On a tripped circuit, or with no circuit, it does nothing, and its ducts and Vents carry no air. Per covered floor tile, it pulls 25 percent harder than the single units.
One unit takes up to 8 Vents, so it covers at most 160 floor tiles. Each Vent goes to the nearest working unit along the ducts that still has room for one. A Vent past every unit's 8 serves nothing, so add a second unit before you add a ninth Vent.
Air Duct
Air Duct is laid with the Utilities run tool, dragged like a pipe. It runs through walls, one duct per tile. There is no town hookup for air, so ducts cannot go on the map edge. That tile is refused with "Air Duct can't go on the map edge."
Reach is counted duct tile by duct tile, not in a straight line, so keep runs direct. A duct on or beside the unit is tile 1. Duct past 40 tiles carries no air. Where two units share a duct, the nearer one counts.
On the Utility Overlay (U) a duct draws as one wide pale cyan band centered on the tile, under the cable and pipe strips. A duct with no air from a working unit draws dim gray. The overlay filter row has an "Air" box that shows or hides ducts. Hovering a duct reads "Air: 12/40 tiles from the unit.", or "Too far from the unit (42/40 tiles).", or "No working HVAC unit on this duct.", with that duct's distance.
Vent

A Vent is live when an Air Duct carrying air runs on its tile or on the tile straight next to it, north, east, south or west. A diagonal duct does not count. The tooltip reads "Live when an Air Duct from a working HVAC Central Unit runs on or beside it."
A live Vent serves the floor of its own room, counted outward from the Vent across indoor floor, up to 20 tiles. Walls, doors and windows stop the count, so each room needs a Vent of its own. A Vent over a tile that is not indoor floor serves nothing.
Vents are ceiling mounts, like lights. A Vent can share a tile with a floor station and does not block the aisle. L shows or hides Vents with the light fixtures. See Ceiling mounts.
Electricity bill
The daily electricity bill counts every unit at its full rating, whether or not it ran that day: 12 kW for each Window AC Unit, 15 kW for each Space Heater, 3 kW for each Box Fan, and 40 kW for each HVAC Central Unit. A unit you do not need still costs you every day. Weather operations days raise the bill. Air Ducts and Vents add nothing.
When it unlocks
In the campaign, the HVAC Central Unit, Air Duct and Vent are locked in Tutorial Facility, Open for Business, People of the Post and Floor Flow. They open at Street Routes and stay open in every later mission. While locked, their buttons are grayed. The lock is titled "Central HVAC" and reads "Central HVAC unlocks in the Street Routes mission." A locked tool that still reaches the map is refused with a notice that names the tool and gives the same line. The Window AC Unit, Space Heater and Box Fan are not under this lock, so they are what you have in the early missions.
In Sandbox, all of them are open from the start.
Installing and removing
- An electrician fits the Window AC Unit, the Space Heater, the Box Fan and the HVAC Central Unit. Electricians keep those jobs even when Maintenance is on duty.
- Air Duct is builder work. City builders lay it, and hired Maintenance also lay duct tiles.
- A Vent is an ordinary object for a builder. Hired Maintenance fit it when they are on duty. A city builder takes it when Maintenance is not on duty.
- Uninstall Object takes out a unit or a Vent. The same trade that fits it comes to take it out.
- Remove Utility marks duct tiles for removal, and a builder or Maintenance pulls them. Hovering a waiting duct removal reads "A builder will pull this." or "Hire Maintenance, or wait for a builder."
- Hold Ctrl and drag a rectangle with the Air Duct tool to uninstall matching ducts into spare stock.


